| PROSTAT PMK-152 Advanced Resistance Kit | |
|
|
|
|
The complete kit for measuring and certifying ESD floors to ANSI/ESD 7.1
|
Kit Contains:
|
| PROSTAT PFC-252 Professional Floor Certification Kit | |
|
The PFC-252 includes Prostat's PRS-812 Resistance System Set with modified 5 pound conductive rubber electrodes and Prostat’s Cable Spacers for exact measurements. The PRS-812 wide range resistance system can take measurements at 10 and 100 volts with accuracy within +/-5%. Also included is the PFK-100 Field Meter Set. The PFK-100 set includes Prostat's unique PFM-711A dual range field meter, CPM-720A charged plate monitor assembly and PCS-730 +/-1 kv charging source. With this instrument set you can measure electrostatic fields, analyze ionizer performance and assess the voltage generation of materials, equipment and personnel. The PGA-710 is a unique electrostatic data analysis device for use with Prostat's PFK-100 Fieldmeter/Charge Plate Monitor Set. It records, plots, analyzes and automatically constructs reports of body voltage generation, electrostatic decay, voltage retention, ionizer performance and other static measuring functions. Its analytical features document and automatically calculate projected levels of typical Human Body (HBM) voltages. It helps determine the risk of equaling or exceeding damaging or hazardous HBM discharge voltages in static sensitive facilities on the floor. The PFC-252 Professional Floor Certification Kit is shipped with an Operator's Manual, Prostat's exclusive Floor Test Manual and the ANSI/ESD S7.1, ANSI/ESD STM97.1 and ANSI/ESD STM97.2 ESD Association Standard Test Methods. Everything you need to certify a floor, or floor and footwear combinations. |
|
|
Everything you need to certify a floor, or floor and footwear combinations
|
Kit Contains:
|
| PROSTAT PGA-710 Autoanalysis System Kit | |
|
The PGA-710 is a unique electrostatic data analysis device for use with Prostat’s PFK-100 Fieldmeter/Charge Plate Monitor Set. It records, plots, analyzes and automatically constructs reports of body voltage generation, electrostatic decay, voltage retention, ionizer performance and other static measuring functions. Its analytical features document and automatically calculate projected levels of typical Human Body (HBM) voltages. It helps determine the risk of equaling or exceeding damaging or hazardous HBM discharge voltages in static sensitive facilities. The Autoanalyzer links to a Field meter’s analog output and lap top computer’s USB using provided cables. Its Autoanalysis Applications software converts your instruments into a digital chart recording system with automatic analysis and reporting features. The PGA-710 will perform measurement and recording functions, perform data analysis, generate charts, then construct and print out complete reports, including the facility’s ambient temperature and relative humidity during each test. The PGA-710 can be used as a freestanding data logger or recorder for later downloading to your computer. It will communicate with your computer via USB or RS-232 COM port. The PGA-710’s unique software will instantly perform mathematical and statistical functions to assist ESD Program Managers and Plant Auditors in defining strengths and weaknesses of the ESDS device transport and handling process. The PGA-710 will calculate the 3-Sigma ranges of Walking and Standing body voltages in your facility, graphically plot the percent probability of equaling or exceeding specific body voltages in the process, and calculate the maximum, minimum and average of voltage generation or decay times. The PFK-100 set includes Prostat's unique PFM-711A dual range field meter, CPM-720A charged plate monitor assembly and PCS-730 ±1 kv charging source. With this instrument set you can measure electrostatic fields, analyze ionizer performance and assess the voltage generation of materials, equipment and personnel. The battery operated PFM-711A Field Meter is a compact "electronic chopper" design with accuracy of +/- 2% at ambient conditions (23ºC and 30%Rh). It features automatic polarity, measurement "hold" button, low battery indicator, high and low ranges, distance ranging lights for accurate and repeatable measurements, manual zero control and a ground snap. With the supplied analog output cable, it can be used in conjunction with an X-Y plotter or any analog data-recording device. The CPM-720A Charge Plate Assembly is 3.25 inches square. It attaches to the PFM-711A field meter for ionizer balancing per ANSI/ESD-S3.1, voltage or charge generation and voltage suppression analysis. The PCS-730 +/- 1 kV Charging Source is used to charge the CPM-720A to +/- 1,000 volts to measure ionizer decay and material decay. These three instruments are match calibrated to work together for accurate and efficient auditing. |
|
|
Measure, Record, Analyze & Report Electrostatic Voltage Generation and Decay Performance on:
|
Kit Contains:
|
| To find out more about ESD Flooring test meters, or to speak to a StaticSmart representative, call (978) 276-0820 or email Sales | |





The PFC-252 Professional Floor Certification Kit is specifically designed for anyone who is verifying floor performance to ANSI/ESD S20.20, IEC 61340-5-1, or other company requirements.